Equipment Details

Product Name: Partially Threaded Spacers
Description:
Maximum size of post permitted: 4.5 kg/m = 3 lb/ft. 6.0 kg/m = 4 lb/ft.EZE-Erect is the strap and spacer system historically used by Franklin Steel Company. Florida Splice is a 200-mm overlap splice with two A307, 9.5-mm x 50-mm (3/8-inch by 2-inch) bolts spaced 150-mm center to center. A spacer is used to separate the webs. The top of the stub is to be 100-mm or less above the ground. Franklin Splice uses unthreaded spacers. Grade 9 bolts, spaced at 100-mm, are needed for multiple post installations. The top of the stub is to be 100-mm or less above the ground. This is the maximum number of breakaway posts permitted within a 2.1-m path. Soil plates measuring 360-mm square and 6.3-mm thick are required on each stub when used in weak soil.
NCHRP Approval: NCHRP Approved
Approval Letter Link: http://safety.fhwa.dot.gov/roadway_dept/road_hardware/breakaway/pdf/ss94.pdf

Contact(s):  

Granger & Associates
132 Northwoods Blvd
Columbus, Ohio 43235
Contact: Mr. Mark S. Granger
Phone: (614) 854-0615

Categories: |